To start off: I was explaining to my friend that I don't have a grounding point in my house (plumbing is PVC, outlets are gcfi protected only, not allowed to drive a grounding rod into the ground, etc...) and that I've just been handling sensitive electronics with just luck and preparation (humidity, moisturizer, no synthetic clothing, etc...) all this time. He told me to just wire myself to a good, multimeter tested, grounding point in a car and that will discharge any built-up static electricity. I'm not smart enough to argue with him on this subject but that doesnt seem the safest. Would that work or should I just keep doing my method? My understanding is that chassis grounding is essentially replacing wires with the frame so the outcome would just be connecting myself to the negative terminal of a car battery.
Tldr: I'm explaining my lack of a grounding point at home for sensitive electronics and is advised by my friend to wire myself to a grounded point in a car to discharge built-up static electricity. However, I'm uncertain about the safety of this suggestion and questions whether my current method of handling electronics with precautions is sufficient.
Edit: lmao people are really getting hung up on the no grounded outlet part. Umm my best explanation I guess is that its an older house that had 2 prong outlets and was "updated" with gfci protected outlets afterwards think the breakers as well. My understanding is that its up to code but I'm not an electrician. As for the plumbing I'm sure there's still copper somewhere but the majority has been updated to pvc over the years. Again it's not my house I don't want to go biting the hand that feeds me. Thank you though, haha
Edit #2: thank you all so much for the helpful advice, I really appreciate all of you!
This is in the US, yes? Don't they have this two phase system of 220V that offers 2x110V, with ground being the center?
Yes, the center (neutral) is connected to ground somewhere, but is not a suitable ground reference - because current on the neutral creates a voltage drop along the neutral conductor. A North American outlet box has Hot (L1), maybe another Hot (L2), Neutral, and also an earth/ground conductor.
Neutral is not ever treated as ground; it’s impermissible to connect it to any bare metallic surface. Other than not being switched, and being the side that ends up on the threads of a light socket, it’s handled the same way as a hot/line conductor. Just like a 240V system.
It would dissipate static fine, if you were allowed to touch it.