this post was submitted on 31 Oct 2023
1 points (100.0% liked)
Home Automation
79 readers
2 users here now
Home automation is the residential extension of building automation.
It is automation of the home, housework or household activity.
Home automation may include centralized control of lighting, HVAC (heating, ventilation and air conditioning), appliances, security locks of gates and doors and other systems, to provide improved convenience, comfort, energy efficiency and security.
Warning: Working with electricity can result in injury, property damage, or even death if it is not done properly. Please keep this in mind while assisting others. If you are not sure about what you are doing, hire a licensed professional.
Rules
- No abusive behaviour. This is a forum for friendly discussion; personal attacks will not be tolerated and you will be banned without warning.
- Referral/affiliate links are NOT ALLOWED!
- NO POLITICS! There are plenty of other communities to discuss them; this is not one.
- When posting project details must be included. Posting a video or image without detail will result in a removed post and may result in a ban.
- Crowdfunding links are not allowed.
- Reposts, low-effort content and karma farming may be removed at the discretion of the mods. Posters may be banned without warning.
founded 11 months ago
MODERATORS
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
I might be missing something here, is this on the basement and why?
So basically there's light bulbs on the stairs and there's 2 ceiling lights in the basement. Are you using e27 bulbs for all the lights?
Walk out basement. The house is on a slope and it's basically a ranch sitting on top of a garage and a sort of mini apartment - living room and master suite.
Downstairs living room has two ceiling fixtures, two receptacles and two switches (at the top of the stairs and as you come in from the garage).
And yup E27 LEDs in the ceiling that I just screw and unscrew to keep the AV system on.
Sorry - should have been more clear.
I still don’t quite understand the need to unscrew and screw the led. Probably some diagram would help. From what I can recommend, without rewiring you could.
Add a smart relay (shelly) to 3 way switch, replace the lights with smart bulbs (cloudfree). Enable decouple mode on the relay, relay stays on. Link the lights to the relay with device group. So toggling on/off would only toggle the smart lights but the AV stays on.
Probably add a condition that the lights in the basement only get toggled off if nobody’s sitting on the couch.